SERVICE

FAULT CAUSE REMEDY

5 Control Power circuit

breaker trips OFF

A


B





C


D

Short on the 120VAC rear
outlets or 14 / 19 pin
receptacles

Internal short circuit




Defective main circuit
breaker

Defective control / auxiliary
transformer

A

B




C

D

Repair the external short circuit

Have an Accredited Thermal Arc
Service Provider check and
repair wiring to both contactors,
fans, main pcb, rear 120VAC
outlets, 14 / 19 pin receptacles
and small control transformer

Have an Accredited Thermal Arc
Service Provider replace the
circuit breaker

Have an Accredited Thermal Arc
Service Provider replace the
control / auxiliary transformer

6 Power Source powers up

but no output or incorrect
output

A

B


C











D


E


F

Check open circuit voltage
is correct

Shorted Output Diode

Check front panel controls
are correct









Defective main control pcb

Defective IGBT or input
rectifier

Possible faulty wiring to
current sensor, or faulty
current sensor

A

B

C










D

E

F

Open Circuit Voltage should be
between 55 – 70VDC

Have an Accredited Thermal Arc
Service Provider replace diode

Set Remote / Local to Remote
Check range of main control

500/500P 350

GTAW 5–560A

5–425A

SMAW 5–560A

5–425A

CAG

5–560A

5–425A

GMAW 10–44V

10–38V

Check contactor control
When the contactor is ON the
indicator LED should be ON.
When the contactor is ON there
should be open circuit voltage
on the output terminals

Have an Accredited Thermal Arc
Service Provider replace pcb

Have an Accredited Thermal Arc
Service Provider replace the
IGBT or input rectifier

Have an Accredited Thermal Arc
Service Provider check wiring to
the current sensor, or replace
faulty current sensor

Power Source Problems (con't)