09 power-master 500p specifications, 09 power-master 500p specifications -7 – Tweco 500P PowerMaster User Manual
Page 23

POWERMASTER 500, 500P, 350
Manual No. 0-4749
2-7
INTRODUCTION
2.09 Power-Master 500P Specifications
Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the specifications or design
of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment previously sold or shipped to the corresponding
changes, updates, improvements or replacement of such items
.
Line Voltage
Line Current
kVA
Eff.
PF
Output
208 VAC/3 Phase
68 Amps
24.5
89%
0.83 450A/38V/100% Duty Cycle
230 VAC/3 Phase
62 Amps
24.7
90%
0.82 450A/38V/100% Duty Cycle
380 VAC/3 Phase
40 Amps
23.7
89%
0.84 450A/38V/100% Duty Cycle
400 VAC/3 Phase
35 Amps
24.2
90%
0.84 450A/38V/100% Duty Cycle
460 VAC/3 Phase
30 Amps
23.9
91%
0.84 450A/38V/100% Duty Cycle
208 VAC/3 Phase
88 Amps
31.7
89%
0.88 500A/40.0/60% Duty Cycle
230 VAC/3 Phase
82 Amps
32.7
89%
0.87 500A/40.0/60% Duty Cycle
380 VAC/3 Phase
50 Amps
32.9
88%
0.87 480A/39.2/60% Duty Cycle
400 VAC/3 Phase
43 Amps
29.8
91%
0.86 480A/39.2/60% Duty Cycle
460 VAC/3 Phase
39 Amps
31.1
90%
0.88 500A/40.0/60% Duty Cycle
Input Data
14.9 in / 378.5 mm
25.5 in /
64.7 cm
26.8 in /
68.0 cm
6.8 in /
172.7 mm
22.0 in / 55.9 cm
23.0 in / 58.4 cm
Art # A-06854
Net Weight: 154 lbs / 70 kg
Line Frequency:
50/60 HZ
Out put Current Range:
5 – 560 Amps
Out put Voltage Range:
10 – 44 Volts
Maximum Output Current:
600 Amps
Maximum Open Circuit Voltage (OCV):
70 Volts (57 Volts for CCC)
Operating Temperature Range:
32-104°F
Input Line Variations:
± 10%
Line Regulation:
± 1%
Load Regulation:
± 1%
Water Protection Class:
IP23S
Figure 2-5: Power-Master 500P Dimensions and Weight