06 power-master 500 specifications, 06 power-master 500 specifications -4 – Tweco 500P PowerMaster User Manual
Page 20

POWERMASTER 500, 500P, 350
INTRODUCTION
2-4
Manual No. 0-4749
Line Voltage
Line Current
kVA
Eff.
PF
Output
208 VAC/3 Phase
68 Amps
24.5
89%
0.83 450A/38V/100% Duty Cycle
230 VAC/3 Phase
62 Amps
24.7
90%
0.82 450A/38V/100% Duty Cycle
380 VAC/3 Phase
40 Amps
23.7
89%
0.84 450A/38V/100% Duty Cycle
400 VAC/3 Phase
35 Amps
24.2
90%
0.84 450A/38V/100% Duty Cycle
460 VAC/3 Phase
30 Amps
23.9
91%
0.84 450A/38V/100% Duty Cycle
208 VAC/3 Phase
88 Amps
31.7
89%
0.88 500A/40.0/60% Duty Cycle
230 VAC/3 Phase
82 Amps
32.7
89%
0.87 500A/40.0/60% Duty Cycle
380 VAC/3 Phase
50 Amps
32.9
88%
0.87 480A/39.2/60% Duty Cycle
400 VAC/3 Phase
43 Amps
29.8
91%
0.86 480A/39.2/60% Duty Cycle
460 VAC/3 Phase
39 Amps
31.1
90%
0.88 500A/40.0/60% Duty Cycle
Input Data
25.5 in /
64.7 cm
26.8 in /
68.0 cm
23.0 in / 58.4 cm
22.5 in / 57.1 cm
14.9 in /
378.5 mm
Art # A-06852
Net Weight: 154 lbs / 70 kg
WARNING
POWER
10A
REMOTE
LOCAL
CONTACTOR
Line Frequency:
50/60 HZ
Out put Current Range:
5 – 560 Amps
Out put Voltage Range:
10 – 44 Volts
Maximum Output Current:
600 Amps
Maximum Open Circuit Voltage (OCV):
70 Volts (57 Volts for CCC)
Operating Temperature Range:
32-104°F
Input Line Variations:
± 10%
Line Regulation:
± 1%
Load Regulation:
± 1%
Water Protection Class:
IP23S
Figure 2-3: Power-Master 500 Dimensions and Weight
2.06 Power-Master 500 Specifications
Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the specifications or
design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment previously sold or shipped to the
corresponding changes, updates, improvements or replacement of such items.