Arcmaster, 160 s, 05 shielding gas selection – Tweco 160 S Arcmaster User Manual
Page 32: 07 welding parameters for steel

ARCMASTER
®
160 S
March 31, 2006
7-2
7.05 Shielding Gas Selection
Alloy
Shielding Gas
Aluminium & alloys
Welding Argon
Carbon Steel
Welding Argon
Stainless Steel
Welding Argon
Nickel Alloy
Welding Argon
Copper
Welding Argon
Titanium
Welding Argon
Table 7 – Shielding gas selection
7.06 TIG Welding Parameters for Low Carbon & Low Alloy Steel Pipe
Electrode Type &
Diameter
Current Range DC
Amperes
Filler Rod for
Root Pass
Joint Preparation
Thoriated 2%
3/32” (2.4 mm)
120 - 170
Yes
Thoriated 2%
3/32” (2.4 mm)
100 - 160
Yes
Thoriated 2%
3/32” (2.4 mm)
90 - 130
No
Table 8– TIG welding parameters for low carbon & low alloy steel pipe
7.07 Welding Parameters for Steel
Base Metal
Thickness
DC Current for
Mild Steel
DC Current
for Stainless
Steel
Tungsten
Electrode
Diameter
Filler Rod
Diameter
(if required)
Argon Gas
Flow Rate
Liters/min
Joint Type
0.040”
1.0mm
35-45
20-30
0.040”
1.0mm
1/16”
1.6mm
5-7
Butt/Corner
40-50
25-35
Lap/ Fillet
0.045”
1.2mm
45-55
30-45
0.040”
1.0mm
1/16”
1.6mm
5-7
Butt/Corner
50-60
35-50
Lap/ Fillet
1/16”
1.6mm
60-70
40-60
1/16”
1.6mm
1/16”
1.6mm
7
Butt/Corner
70-90
50-70
Lap/ Fillet
1/8”
3.2mm
80-100
65-85
1/16”
1.6mm
3/32”
2.4mm
7
Butt/Corner
90-115
90-110
Lap/ Fillet
3/16”
4.8mm
115-135
100-125
3/32”
2.4mm
1/8”
3.2mm
10
Butt/Corner
140-165
125-150
Lap/ Fillet
¼”
6.4mm
160-175
135-160
1/8”
3.2mm
5/32”
4.0mm
10
Butt/Corner
170-200
160-180
Lap/ Fillet
Table 9 – DC TIG welding parameters