Aluminum, 100a, N2 plasma / h2o secondary – Tweco XTTM-301 User Manual
Page 86

APPENDIX
A-12
Manual 0-4768
Aluminum
100A
N2 Plasma / H2O Secondary
NOTE
Ohmic sensing is not recommended with water shield. Water on the
plate interferes electrically with the ohmic sensing system.
Art # A-06747
Shield Cap
35-1053
35-1089
35-1041
Cartridge
Shield Cup
35-1016
Plasma Gas Distributor
Shield Gas Distributor
35-1020
35-1034
35-1272
Tip
Electrode
Shield (H2O)
(ga)
(in)
(in)
Ball
psi
Ball*
(volts)
(in)±0.005
(ipm)
(in)
(sec)
10
0.135
45
90
5
158
0.188
170
0.300
0.0
3/16
0.188
45
90
5
165
0.188
80
0.300
0.3
1/4
0.250
45
90
5
167
0.188
60
0.300
0.3
3/8
0.375
45
90
5
172
0.188
50
0.300
0.3
1/2
0.500
45
90
5
168
0.188
35
0.300
0.4
5/8
0.625
45
90
5
179
0.188
20
0.350
0.5
Shield (H2O)
Ball
bar
Ball*
(volts)
(mm)
±0.125
(mm/min)
(mm)
(sec)
45
6.2
5
161
4.8
3350
7.6
0.3
45
6.2
5
165
4.8
1960
7.6
0.3
45
6.2
5
167
4.8
1640
7.6
0.3
45
6.2
5
170
4.8
1390
7.6
0.3
45
6.2
5
171
4.8
1210
7.6
0.4
45
6.2
5
169
4.8
970
7.6
0.4
45
6.2
5
176
4.8
610
8.9
0.6
Bold type indicates maximum piercing parameters.
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
100A Al (N2/H2O)
Initial
Piercing
Height
Pierce
Delay
Material
Thickness
** Arc
Voltage
Cut Flow Rates / Pressures
Plasma (N2)
** Arc
Voltage
Torch
Working
Height
15
* Ball setting for shield water is set using a line pressure of 55 PSI / 3.8 bar
12
10
8
6
5
4
Travel
Speed
Material
Thickness
(mm)
Cut Flow Rates / Pressures
Plasma (N2)