Tweco XTTM-301 User Manual
Page 18

INTRODUCTION
2-4
Manual 0-4768
3. Cutting Range
Most materials up to 1 inch (25.4 mm)
Up to 1/2 inch (12.7 mm) for production speed cutting
4. Pierce Rating
1/2 inch (12.7 mm)
5. Transfer Distance
1/8 - 1/4 inch (3-6 mm)
6. Torch Parts
Shield Cup, Shield Cap, Secondary ('Shield') Gas Distributor, Tip, Plasma Gas Distributor, Electrode, Cartridge
Cartridge
Shield Cup
Art # A-04741
Electrode
Tip
Plasma Gas
Distributor
Shield Gas
Distributor
Shield Cap
7. Gas Requirements
Gas
Quality
Minimum Pressure
Flow
O2 (Oxygen)
99.5% Purity
(Liquid recommended)
90 psi
6.2 bar / 620 kPa
83 scfh (2350 l/h)
N2 (Nitrogen)
99.5% Purity
(Liquid recommended)
<1000 ppm O2, <32
ppm H2O)
90 psi
6.2 bar / 620 kPa
278 scfh (7872 l/h)
Compressed
or Bottled Air
Clean, Dry,
Free of Oil (see Note 1)
90 psi
6.2 bar / 620 kPa
82 scfh (2313 l/h)
H35 (Argon-Hydrogen)
H35 = 35% Hydrogen,
65% Argon
99.995% Purity
(gas liquid
recommended)
90 psi
6.2 bar / 620 kPa
77 scfh (2180 l/h)
H2O (Water)
See Note 2
50 psi (3.5 bar)
3 - 9 gph (13 - 40 lph)
Gas Pressures, Flows, and Quality Requirements
Note 2: The tap water source does not need to be deionized, but in water systems with
extremely high mineral content a water softener is recommended. Tap water with high levels of
particulate matter must be filtered.
Note 1: The air source must be adequately filtered to remove all oil or grease. Oil or grease
contamination from compressed or bottled air can cause fires in conjunction with oxygen.
8. Parts - In - Place (PIP)
The torch is designed for use with a power supply which senses coolant return flow to confirm that torch parts are
in place. If coolant return flow to the power supply is absent or insufficient the power supply will not provide
power to the torch. Coolant leakage from the torch also indicates that torch parts are absent or installed improperly.
9. Type of Cooling
Combination of gas stream through torch and liquid cooling.