INSTALLATION
3-6
Manual 0-2962
6. Connect the control circuit connectors on the Torch
Leads to the mating connectors on the Remote
Pendant Adapter and Power Supply Adapter (see
Warning).
WARNING
There are two additional connectors that are
not used and must be taped out of the way to
prevent contacting the Negative / Plasma or
Pilot Leads.
7. Remove the top nut and washer from the Pilot Stud
on the power supply bulkhead.
8. Place the Torch Leads Pilot lead terminal on onto
the stud and secure with the nut and washer re-
moved in the above Step.
A-03675
Torch Lead
Assembly
Control Circuit
Connectors
Open
Open
Power Supply
Adapter
Pilot Lead
Negative/Plasma
Lead
Adapter
Connector
Pilot Lead Stud
Negative/Plasma
Lead Connection
Note: Actual Bulkhead
configuration may
differ from that shown.
Remote Pendant
Adapter Wire Harness
Bulkhead Connection - Unshielded Machine Torch with
O2B Fittings and Remote Pendant Adapter
9. Connect the Torch Leads connectors and the
remote pendant adapter connector to the power
supply adapter as shown.
Remote Pendant
Adapter Wire
Harness
A-03676
Pilot Lead
Torch Lead
Assembly
Negative/Plasma
Lead
Control Circuit
Connectors
Open
Open
Power Supply
Adapter
Bulkhead Connection Detail - Unshielded Machine Torch
with O2B Fittings and Remote Pendant Adapter
10. Tighten the Through - Hole protector onto the Torch
Leads or ATC Adapter Leads Assembly.
11. Connect the remote pendant to the remote pendant
adapter.
12. Check the torch for proper consumable parts.
CAUTION
The torch parts must correspond with the type
of operation. Refer to Section 4.04, Torch Parts
Selection.
D. Remote Pendant Control (Optional)
In mechanized applications an Adapter connects the
remote pendant control to the Power Supply.
Connect the remote pendant control cable to the torch
leads by aligning the control cable connector with
the adapter on the torch leads. Press the connector
into the adapter. Turn the locking ring to secure the
connection.