Appendix 1: input wiring requirements – Tweco Merlin 6000 Slave PS User Manual
Page 35

Manual 0-2570
A-1
APPENDIX
APPENDIX 1: INPUT WIRING REQUIREMENTS
NOTES
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER
use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.
In p u t
P o w er In p u t
C u r r e n t
S u g g e st ed S iz es ( S ee N o t e)
V o lt ag e
F r eq .
3- P h
3- P h
F u s e ( A m p s )
W ir e ( A W G )
W ir e ( C a n ad a )
( V o lt s)
( H z )
( kV A )
( A m p s )
3- P h
3- P h
3- P h
20 0
50 /60
34
98
11 0
A W G 2
2
20 8
50 /60
34
95
11 0
A W G 2
2
22 0
50 /60
34
89
10 0
A W G 2
2
23 0
50 /60
34
85
10 0
A W G 4
2
38 0
50 /60
34
51
60
A W G 6
6
41 5
50 /60
34
47
60
A W G 8
6
46 0
50 /60
34
42
50
A W G 8
6
50 6
50 /60
34
40
45
A W G 8
6
57 5
50 /60
34
34
40
A W G 8
6
Li ne V o l ta ges w i th S ugg es ted C i r c ui t P r ote c ti on and W i r e S i z es
B as ed on N a ti o nal E l ec tr i c C o de and C an adi an E l ec tr i c a l C od e