Cutmaster a40 – Tweco A40 CutMaster User Manual
Page 18

CUTMASTER A40
2-2
INTRODUCTION
Manual 0-4978
2.04 POWER SUPPLY SPECIFICATIONS
CutMaster A40 Power Supply Specifications
Input Power
208 / 230 VAC (187 - 253 VAC), Single Phase, 60 Hz
230 VAC (187 - 253 VAC), Three Phase, 50/60 Hz
380 VAC (360 - 440 VAC), Three Phase, 50/60 Hz
400 VAC (360 - 440 VAC), Three Phase, 50/60 Hz
460 VAC (414 - 506 VAC), Single Phase, 60 Hz
460 VAC (414 - 506 VAC), Three Phase, 60 Hz
600 VAC (540 - 630 VAC), Three Phase, 60 Hz
Input Power Cable
Power Supply includes input cable.
Cable for 208/230V input power includes molded plug.
Output Current
20 - 60 Amps, Continuously Adjustable
Power Supply Gas
Filtering Ability
Particulates to 5 Microns
CutMaster A40 Power Supply Duty Cycle *
Ambient Temperature
Duty Cycle Ratings @ 40° C (104° F)
Operating Range 0° - 50° C
IEC Rating
All Units
Duty Cycle
40%
60%
100%
Current
60 Amps
50 Amps
30 Amps
DC Voltage
104
100
92
* NOTE: The duty cycle will be reduced if the primary input power (AC) is low
or the output voltage (DC) is higher than shown in this chart.
NOTE
IEC Rating is determined as specified by the International Electro-Technical Commission. These specifications include
calculating an output voltage based upon power supply rated current. To facilitate comparison between power sup-
plies, all manufacturers use this output voltage to determine duty cycle.
Power Supply Dimensions & Weight
Ventilation Clearance Requirements
20.8"
0.528 m
43 lb / 19.5 kg
10"
254 mm
13.78"
350 mm
Art # A-08305
6"
150 mm
24"
610 mm
6"
150 mm
6"
150 mm
Art # A-07925_AB