03 common faults – Tweco 50 CutMaster User Manual
Page 28
![background image](/manuals/595065/28/background.png)
SERVICE
5-2
Manual 0-2805
A-02476
Filter
Element
(Cat. No. 9-7741)
Housing
Cover
Barbed
Fitting
Spring
Assembled Filter
O-ring
Optional Single-Stage Filter Element Replacement
6. Wipe inside of housing clean, then insert the re-
placement Filter Element open side first.
7. Replace Housing on Cover.
8. Reattach gas supply hose to barbed fitting.
NOTE
If unit leaks between housing and cover, inspect the
"O" Ring for cuts or other damage.
D. Optional Two-Stage Filter Element
Replacement
These instructions apply to any power supply where the
optional Two-Stage Filter has been installed.
The Two-Stage Air Filter has two Filter Elements. When
the Filter Elements become dirty the Power Supply will
continue to operate but cut quality may become unaccept-
able. Refer to Section 6, Parts List, for replacement filter
element catalog number.
1. Remove power from power supply.
2. Shut off air supply and bleed down system before
changing Filter Elements.
WARNING
Always turn off the air supply and bleed the system
before disassembling the Filter Assembly as injury
could result.
3. Loosen the two bolts on the top of the Filter Assem-
bly enough to allow the Filter Elements to move
freely.
First & Second
Stage
Cartridges
(as marked)
A-02942
Two-Stage Filter Replacement
4. Note the location and orientation of the old Filter
Elements.
5. Slide out the old Filter Elements.
6. Slide the replacement Filter Elements into the Fil-
ter Assembly, with the same orientation as noted
in Step 4 above.
7. Hand tighten the two bolts evenly, then torque each
bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm).
8. Slowly apply air pressure to the assembly, check-
ing for leaks.
5.03 Common Faults
1. Insufficient Penetration
a. Cutting speed too fast
b. Torch tilted too much
c. Metal too thick
d. Worn torch parts
e. Cutting current too low
f. Non-Genuine Thermal Dynamics parts used