tekmar 530 Thermostat Installation User Manual
Page 24

24 of 28
© 2011
D 530 - 12/11
Error M
e
s
s
ag
e
s
(
2
of 2
)
Error Messag
e
Descrip
tion
ADDRESS ERR
OR
This t
hermostat and ano
ther de
vice ha
ve
been manuall
y giv
en t
he same t
ekmarNe
t
®
addr
ess.
Err
or clears aut
omaticall
y once t
his t
hermostat is giv
en a ne
w manuall
y se
t addr
ess or if t
h
e
thermostat is se
t t
o
aut
omatic addr
essing.
R
OOM SENSOR SHORT CIR
CUIT
The built-in air t
e
mper
atur
e sensor has a shor
t cir
cuit f
ault.
This err
or canno
t be field r
epair
ed.
Contact y
our wholesaler or t
ekmar sales r
epr
esentativ
e f
or de
tails on r
epair pr
ocedur
es.
R
OOM SENSOR OPEN CIR
CUIT
The built-in air t
e
mper
atur
e sensor has an open cir
cuit f
ault.
This err
or canno
t be field r
epair
ed.
Contact y
our wholesaler or t
ekmar sales r
epr
esentativ
e f
or de
tails on r
epair pr
ocedur
es.
AIR MAS
TER ERR
OR
Ther
e ar
e tw
o t
h
ermostat’
s on t
he t
ekmarNe
t
®
sy
st
em se
t as t
he same Air Gr
oup mast
e
r.
The cooling
sy
st
em will no
t operat
e while t
his err
or message is pr
esent.
Err
or clears once t
his t
hermostat or t
he o
ther t
hermostat’
s air gr
oup mast
er number is changed t
o
an unused air gr
oup number
.
- 032 Timer (4 pages)
- 033 4 Timer (12 pages)
- 040 RDM (4 pages)
- 054 RTU (2 pages)
- 055 RTU (2 pages)
- 060 RTU (2 pages)
- 062 RTU (4 pages)
- 063 RTU (8 pages)
- 070 Outdoor Sensor (4 pages)
- 071 Universal Sensor (4 pages)
- 072 10k Slab Sensor (2 pages)
- 073 10k Slab Sensor (2 pages)
- 076 Indoor Sensor (4 pages)
- 077 Indoor Sensor (4 pages)
- 078 Universal Sensor (4 pages)
- 079 Slab Sensor (4 pages)
- 081 Three Outdoor Sensor Module (4 pages)
- 082 Universal Sensor (4 pages)
- 083 Duct Sensor (4 pages)
- 084 Indoor Sensor (4 pages)
- 085 10k Solar Sensor (2 pages)
- 086 Humidity & Temperature Sensor (8 pages)
- 090 Snow/Ice Sensor (8 pages)
- 095 Snow Sensor (8 pages)
- 150 One Stage Setpoint Control (4 pages)
- 152 Two Stage Setpoint Control (4 pages)
- 153 Mixing Setpoint Control (4 pages)
- 155 Difference Setpoint Control (4 pages)
- 156 Difference Setpoint Control (12 pages)
- 157 Difference Setpoint Control (16 pages)
- 161 Setpoint Control Installation (36 pages)
- 161 Setpoint Control User Manuals (12 pages)
- 162 Setpoint Control Installation (32 pages)
- 162 Setpoint Control User Manuals (12 pages)
- 256 Boiler Control (20 pages)
- 257 DHW Control (12 pages)
- 260 Boiler Control (20 pages)
- 261 Boiler Control (20 pages)
- 262 Boiler Control Installation (36 pages)
- 262 Boiler Control User Manuals (4 pages)
- 263 Boiler Control (36 pages)
- 264 Boiler Control (32 pages)
- 265 Boiler Control (36 pages)
- 268 Boiler Control (32 pages)
- 269 One Stage Steam Control (12 pages)