tekmar 512 Programmable Thermostat Installation User Manual
Page 7
7 of 20
© 2009
D 512 - 09/09
Adjust Menu (1 of 4)
MODE
Current mode of operation of the thermostat.
OFF, HEAT
OFF, COOL, AUTO, HEAT
ROOM HEAT (No Schedule)
Desired temperature for heating.
(Must have an active air sensor and be set to either Heat or Auto.)
35 to 100°F (1.5 to 38.0°C)
ROOM COOL (No Schedule)
Desired temperature for cooling.
(Must have an active air sensor and be set to either Cool or Auto.)
35 to 100°F (1.5 to 38.0°C)
SLAB MINIMUM (No Schedule)
Minimum slab temperature.
(Must have an active slab sensor.)
OFF, 34 to 122°F (OFF, 1.0 to 50.0°C)
ROOM HEAT WAKE
Desired temperature for heating during Wake.
(Must have an active air sensor and be set to either Heat or Auto.)
35 to 100°F (1.5 to 38.0°C)
ROOM HEAT UnOcc
Desired temperature for heating during UnOccupied.
(Must have an active air sensor and be set to either Heat or Auto.)
35 to 100°F (1.5 to 38.0°C)
ROOM HEAT Occ
Desired temperature for heating during Occupied.
(Must have an active air sensor and be set to either Heat or Auto.)
35 to 100°F (1.5 to 38.0°C)
ROOM HEAT Sleep
Desired temperature for heating during Sleep.
(Must have an active air sensor and be set to either Heat or Auto.)
35 to 100°F (1.5 to 38.0°C)