Room Temperature Unit (RTU) 062, 063

A single RTU can be connected to the mixed side (tN1/tN2) of the Universal Reset Control 363 in order to
provide a one zone mixed water temperature system. When multiple zones are required for the mixed side,
use either a tekmar zone control or, through the mix demand input, on / off zone control. When using an RTU,
several items related to the mixing side of the heating system are no longer available in the control’s display.
These items will be available only in the RTU’s display. Also, the number of items that are available on the
RTU will depend on the type of RTU (062 or 063) that is connected to the control.

35 to 100˚F
(2 to 38˚C)

Current room air temperature.

14 to 167˚F
(-10 to 75˚C)

Target room air temperature.

-67 to 149

°F

(-55 to 65

°C)

Current slab sensor temperature. This item is only available if a
tekmar slab sensor is connected to a RTU 063.

-58 to 167

°F

(-50 to 75

°C)

363 RTU View Menu

Item

LT

D

USER

Range

062 063

Current outdoor air temperature as measured by the outdoor sensor.

Item

Menu

UnOcc 1

°F

View

Heat

The units of measure that all of the temperatures are to be displayed
in by the control.

˚F, ˚C

The operating mode for the back lighting of the LCD and the time
until the control returns to the view menu after any button was
pressed.

If

Backlight is set to

OFF

,

the control returns after 10

seconds and the backlight stays off.

If Backlight is set to

30 SEC

,

the control returns after 30 seconds and the backlight stays on for
30 seconds after any button press.

If Backlight is set to

ON

,

the

control returns after 90 seconds and the backlight stays on.

OFF, 30 sec, ON

The access level that is to be used by the control.
DIP switch =

Only qualified service people should adjust items in the

ADV

(Advance)

and

INST

(Installer) access levels.

ADV, INST, USER, LTD

363 Misc (Miscellaneous) Menu

Item

LT

D

USER

Range

NONE, TMPY Occ, PERM
Occ, TMPY UnOcc, PERM
UnOcc, AWAY

363 Schd (Schedule) Menu

Item

LT

D

USER

Range

None

– No override.

TMPY Occ

– Overrides to Occupied setting for 3 hours.

PERM Occ

– Overrides to Occupied setting until new

override is selected.

TMPY UnOcc

- Overrides to UnOccupied for 3 hours.

PERM UnOcc

– Overrides to UnOccupied setting until

new override is selected.

AWAY

– Room & WWSD temperature at 62˙F (17˙C), no DHW.

The type of setback override that is in effect.

DIP switch =

Setback

AWAY is available even if DIP

≠ Setback

Note: Depending on the settings the installer make in the control, certain menu items may not appear.

-67 to 149˚F
(-55 to 65˚C)

-67 to 149˚F
(-55 to 65˚C)

The highest DHW tank or Storage tank temperature since this item
was last cleared. To clear this item, press both the and buttons
until ‘CLR’ is displayed.

The lowest DHW tank or Storage tank temperature since this item
was last cleared. To clear this item, press both the and buttons
until ‘CLR’ is displayed.

0 to 255˚F
(-18 to 124˚C)

0 to 255˚F
(-18 to 124˚C)

363 Monitor Menu

Item

LT

D

USER

Range

The highest outdoor air temperature recorded since this item was
last cleared. To clear this item, press and hold the and buttons
until ‘CLR’ is displayed.

The lowest outdoor air temperature recorded since this item was
last cleared. To clear this item, press and hold the and buttons
until ‘CLR’ is displayed.