9.2.8 Inverter compressor drive error diagnosis and solution(P4)

Check if the wiring between main
PCB and compressor connected by
error and if the wires and connectors
are broken?

Correct the connection or

replace the wires and

connectors.

Yes

No

Check if the IPM installed correctly.

Correct the installation,

tighten the screws and

apply silicon grease.

No

IPM continuity check. Check if the
IPM terminal resistance values are
uniform.

Yes

Replace the IPM board or replace

the main PCB if the IPM board and

main PCB are integrated together.

No

Check if the outdoor fan runs

properly or the outdoor unit

ventilation is good.

Yes

No

Refer to the solution of fan speed

has been out of control

malfunction . Find out the cause

and have it solved.

Yes

Check if the compressor resistance

values are uniform .

No

Replace the compressor.

Yes

Replace the outdoor main PCB if the

main PCB and IPM are separate.