9.2.3 Zero crossing detection error diagnosis and solution(E2)

Check if the connections and

power supply is normal?

Correct the connections. Turn on the
unit when the power supply is good.

No

Yes

Indoor main PCB is

defective. Replace indoor

main PCB.

9.2.4 Indoor fan speed has been out of control diagnosis and solution(E3)

Shut off the power supply

and turn it on 5 seconds

later. Is it still displaying

the error code?

Shut off the power supply ,
rotate the fan by hand.
Does it rotate properly?

The unit operates normally.

Find out the cause and

have it solved. For

example, check

whether the fan is

blocked or the bearing

is broken?

Check the wires of fan

motor. Are all the

connections good?

No

Yes

No

Correct the connections.

No

Yes

Check whether the main PCB is

normal through index 2?

Yes

Yes

Check whether the fan

motor is normal through

index 1?

Yes

Replace the fan

motor

Replace the

main PCB.

The

malfunction is

solved?

No

No

If the

malfunction is

still existing,

replace the

main PCB

No