7. Operation characteristics

CAUTION:

1. If air conditioner is used outside of the above conditions, certain safety protection features may

come into operation and cause the unit to function abnormally.

2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the

surface of the air conditioner may attract condensation. Please set the vertical air flow louver to its

maximum angle (vertically to the floor), and set HIGH fan mode.

3. Optimum performance will be achieved within this operating temperature.

Temperature

Mode

Cooling operation

Heating operation

Drying operation

Room temperature

≥17℃(62℉)

≤30℃(86℉)

>10℃(50℉)

Outdoor temperature

0℃~50℃

(32℉~122℉)

-15℃~30℃

(5℉~86℉)

0℃~50℃

(32℉~122℉)

-15℃~50℃(5℉~122℉)

(For the models with

low temperature cooling system)