9. Troubleshooting

9.1 Indoor Unit Error Display

Display

Operation lamp flash times

Timer lamp

Failure

E0

1

X

EEPROM error

E1

2

X

Indoor and outdoor communication error

E2

3

X

Zero crossing detection error

E3

4

X

Indoor fan speed has been out of control

E4

5

X

Indoor room temperature sensor T1 open

circuit or short circuit

E5

6

X

Evaporator coil temperature sensor T2 open

circuit or short circuit

EC

7

X

Refrigerant leak detection error

F1

2

O

Outdoor temperature sensor T4 open circuit or

short circuit

F2

3

O

Condenser coil temperature sensor T3 open

circuit or short circuit

F3

4

O

Compressor discharge temperature sensor T5

open circuit or short circuit

F4

5

O

Outdoor EEPROM parameter error

P0

1

IPM malfunction or IGBT over-strong current

P1

2

Over voltage or too low voltage protection

P2

3

Temperature protection of compressor

top(only for 24k models)

P4

5

Inverter compressor drive error

O(light) X(off)