INSTALLATION INSTRUCTIONS FOR SHIELD REQUIRED FOR COMBUSTIBLE FLOOR

This shield for combustible floors is intended for use only with the following Burnham oil-fired boilers:

Use Part Number 6183504 for the following models:

RSA85 RSA110 RSA125 RSA135

ADDS 4-3/16” TO BOILER HEIGHT

Use Part Number 6183505 for the following models:

RSA170 RSA195 RSA240 RSA285

ADDS 5-3/8” TO BOILER HEIGHT

1) Place shield on combustible floor with “TOP” surface

upward and “FRONT” surface directly below the

expected position of the oil burner.

2) Locate shield such that clearances to combustible walls

are as indicated in Figure 26. These dimensions will

assure that the boiler jacket will be at least 18” from

the side and rear walls and 48” from the front wall, as

required by ANSI/NFPA 31.

3) Fasten shield to combustible floor to keep shield from

shifting position during setting of boiler.

4) Set boiler squarely on top of shield such that base plate

of boiler rests flat on top surface of shield and does not

over-hang shield on any side. Confirm clearance to

combustible walls. Refer to Figure 2.

5) Do not enclose boiler (including shield) on all four

sides. Boiler may be enclosed on any three sides while

maintaining minimum clearances shown in Figure 2 for

each of those three sides.

Figure 2