beautypg.com

10-3. bas-326f-0, 10-4. adjusting the air pressure – Brother BAS-311F-L User Manual

Page 57

background image

9. STANDARD ADJUSTMENTS

BAS-311F-0, 311F-L, 326F-0

50

(1)

(2)

(4)

(3)

(2)

(4)

(3)

(5)

Scale

20 mm

(5)

(2)

(4)

(1)

(3)

9-10-3. BAS-326F-0

1. Turn on the air, and then press the presser lifter switch (1) to raise the presser foot (2) .
2. Loosen the bolts (5) of presser lifter lever UR (3) and presser lifter lever UL (4).
3. Place a scale against the presser foot (2), and then move presser lifter lever UR (3) and presser lifter lever UL (4) up

and down to adjust so that the amount of presser lift is 20 mm from the top of the needle plate.

4. After adjusting the lift amount (20 mm), tighten the bolts (5) of presser lifter lever UR (3) and presser lifter lever UL (4).

9-10-4. Adjusting the air pressure

1. Air pressure should be 0.5 MPa.

The air pressure can be adjusted by pulling up and
turning the control knob (2) on the integrator (1).
After adjustment is complete, push the control knob (2)
downward to lock it.

2. If water stands in the bottle of the integrator (1), turn

the drain cock (3) in the direction indicated by an arrow
to drain the water.

Note

Open the air cock (4) slowly.

1268S

1304S

1269S

1270S

1271S

This manual is related to the following products: