beautypg.com

10. connecting the ground wire, Caution – Brother BAS-311F-L User Manual

Page 18

background image

3. INSTALLATION

BAS-311F-0, 311F-L, 326F-0

11

3-10. Connecting the ground wire

CAUTION

Be sure to connect the ground. If the ground connection is not secure, you run the risk of receiving a serious
electric shock.

Connection method for 3-phase power supply

3-11. Connecting the cords (Installing the operation panel)

1. Assemble the operation panel stand (1) and cushion A

(2). Then insert the bolts (4) together with the washers
(3) into the three holes from above, and then tighten
the nuts (5), washers (6) and cushion B (7) from below
to secure the assembly.
Note

Tighten until the thickness of cushion B (7)
becomes about 1 mm.

2. Pass the cords of the control panel assembly through

the hole in the operation panel stand (1).

3. Attach the rubber sheet (8) to the hole in the operation

panel stand (1) and then secure it with the bolt (9).

4. Insert the cord into the control box through the hole at

the side of the box. Refer to page 13.

5. Secure the cord with the staples ( in two places).

Note

When opening the front cover, check that the code
does not touch it.

Red
White
Black
Yellow/Green

3-phase
power supply
Yellow/Green

0064Q

Connect to
ground

(4)
(3)

(8)

(1)

(9)

(2)

(7)

(6)

(5)

1 mm

40 mm

Front cover

1587Q