beautypg.com

10. adjusting the two-step work clamp lift amount, 10-1. bas-311f-0 solenoid type, 10-2. bas-311f-0, 311f-l pneumatic type – Brother BAS-311F-L User Manual

Page 56

background image

9. STANDARD ADJUSTMENTS

BAS-311F-0, 311F-L, 326F-0

49

(3)

(2)

(1)

20 mm

(1)

(3)

(2)

(3)

(2)

(4)

scale

20 mm

(4)

9-10. Adjusting the two-step work clamp lift amount

The maximum work clamp lift amount is 25

1 mm (for solenoid type) or 30

1 mm (for pneumatic type) from the

top of the needle plate.

The lift amount for each model is adjusted as shown in the table at the time of shipment.

type

Solenoid type

(BAS-311F-0 only)

Pneumatic type

Lift amount

20 mm

9-10-1. BAS-311F-0 Solenoid type

1. Turn the power switch OFF.
2. Loosen the bolts (2) of work clamp arm lever F (1) .
3. Plase a scale against the work clamp (3), and then move work clamp arm lever F (1) up or down to adjust so that the

amount of lift above the top of the needle plate is 20 mm.

4. After adjusting the lift amount (20 mm), tighten the bolts of work clamp arm lever F (1) .

9-10-2. BAS-311F-0, 311F-L Pneumatic type

1. Turn on the air, and then press the work clamp lifter switch (1) to raise the work clamp (2) .
2. Loosen the bolts (4) of work clamp arm lever F (3) .
3. Place a scale against the work clamp (2), and then move work clamp arm lever F (3) up and down to adjust so that the

lift amount is 20 mm.

4. After adjusting the lift amount (20 mm), tighten the bolts (4) of work clamp arm lever F (3).

1264S

1265S

1266S

1267S

This manual is related to the following products: