Banner D10 Expert with Numeric Display—Discrete User Manual
Page 7

Push Button
Remote
0.04 sec. ≤ T ≤ 0.8 sec.
Result
Access Dy-
namic
TEACH
Mode
Press and hold Dynamic
(+) button.
Hold remote line low (to
ground).
• Display flashes “dYn”
• Arrow icon turns red
TEACH
Sensing
Conditions
Present Output ON/OFF
conditions while continu-
ing to hold Dynamic but-
ton.
Present Output ON/OFF con-
ditions while continuing to
hold remote line low (to
ground).
Return to
RUN Mode
Release Dynamic button. Release remote line/switch.
TEACH conditions accep-
ted
• Display flashes
“PASS,” followed by a
number (denoting con-
trast); see
on page 6
• Sensor returns to RUN
mode with new settings
• Arrow icon turns green
TEACH conditions unac-
ceptable
• Display flashes “FAIL”
• Arrow icon remains red
• Sensor returns to RUN
mode (Arrow icon turns
green) without chang-
ing settings
D10 Expert™ - Analog and Discrete Outputs
P/N 65448_web
rev. F
www.bannerengineering.com - tel: 763-544-3164
7