Installation, Stallation – Banner D10 Expert with Numeric Display—Discrete User Manual
Page 16

Output Rating
Discrete Output: 150 mA, max. load
OFF-state leakage current: < 10 μA at 24V dc
ON-state saturation voltage: NPN: < 1.5V at 150 mA
load; PNP < 2.5V at 150 mA load
Analog Output: 4-20 mA or 0-10V dc
Load: 4-20 mA Models: 100Ω max. impedance; 0-10V
dc Models: 1 MΩ min. impedance
Output Protection Circuitry
Protected against false pulse on power-up and continu-
ous short-circuit
Output Response Time
Discrete Output: Programmable, 50 microseconds,
200 microseconds, 1 millisecond, 2.5 milliseconds
Analog Output: 1 millisecond
NOTE: < 1
second delay
on power-up;
outputs do not
conduct during
this time.
Operating Conditions
Temperature: -20° to +55°C (-4° to +131°F)
Storage: -20° to +80°C (-4° to +175°F)
Max. Rel. Humidity: 90% @ 50°C (non-condensing)
Number
of Devi-
ces,
Stacked
Ambient
Temper-
ature
Rating
Load
Specifi-
cation
3
55ºC
(131ºF)
150 mA
7
50ºC
(122ºF)
50 mA
10
45ºC
(113ºF)
50 mA
Installation
35 mm DIN rail or included mounting bracket
Certifications
Installation
Install the product on a 35 mm DIN rail or the included mounting bracket.
Plastic Fiber
Emitter Port
Plastic Fiber
Receiver Port
Slides Up to
Release Fibers
D10 Expert™ - Analog and Discrete Outputs
16
www.bannerengineering.com - tel: 763-544-3164
P/N 65448_web
rev. F