beautypg.com

Single-point dark set - discrete only – Banner D10 Expert with Numeric Display—Discrete User Manual

Page 10

background image

Push Button

Remote

0.04 seconds < T < 0.8 seconds

Result

T

T

T

T

T

T

T

• Sensor returns to RUN

mode with new settings

• Arrow icon turns green

Threshold conditions un-
acceptable

• Display flashes “FAIL

and returns to “1St

• Arrow icon remains red
• After 60 seconds, sen-

sor returns to RUN
mode (Arrow icon turns
green) without chang-
ing settings

Single-Point Dark SET - Discrete Only

Threshold position

adjusted by

Manual Adjust

Sensor positions

threshold slightly above

the presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Condition

Presented

Figure 11. Single-Point Dark SET (Light Operate

shown)

• Sets a threshold slightly above the taught condition (see

Figure 11.

Single-Point Dark SET (Light Operate shown)

on page 10)

• Any condition lighter than the threshold condition causes the output to

change state

• Threshold position is adjustable using the “+” and “-” buttons (see

Manual Adjust

on page 11)

• Recommended for applications where only one condition is known, for

example a stable dark background with varying lighter targets

A single sensing condition is presented, and the sensor positions a thresh-
old slightly above the taught condition. When a condition lighter than the
threshold is sensed, the output either turns ON or OFF, depending on the
Light/Dark Operate setting (see

Sensor Setup

on page 12).

Mode

Threshold Offset (counts

above taught signal value)

Super High-Speed

30

High-Speed

22

High-Power

9

Super High-Power

6

Figure 12. Dark SET Threshold Offset

Dark SET and Light/Dark Operate Selection
Dark SET teaches the Output OFF condition and forces the sensor into
Light Operate (LO) mode. The sensor can be reconfigured to Dark Oper-
ate (DO) mode after the condition has been taught (see

Sensor Setup

on

page 12).

Push Button

Remote

0.04 seconds < T < 0.8 seconds

Result

Access SET
Mode

Press and hold Static (-)
button > 2 seconds.

Single-pulse the remote line.

T

Push Button

• Display flashes “1St
• Arrow icon turns red

D10 Expert™ - Analog and Discrete Outputs

10

www.bannerengineering.com - tel: 763-544-3164

P/N 65448_web

rev. F

This manual is related to the following products: