Banner D10 Expert with Numeric Display—Discrete User Manual
D10 expert™ - analog and discrete outputs, Features, Models

Advanced sensor for use with plastic fiber optics
Features
• Easy-to-set automatic Expert-style TEACH options* including static, dynamic, and
single-point programming plus manual adjustment for fine-tuning
• 16-bit microcontroller and 12-bit Analog-to-Digital converter for high-performance,
low-contrast sensing
• Easy-to-read 4-digit display for TEACH and signal strength readout, plus indicators
for a continuous readout of operating status (user configurable)
• Models available with one scalable Analog output (4 to 20 mA or 0 to 10V) and one
Discrete output (PNP or NPN)
• Four-mode power and speed selection with automatic cross-talk avoidance circuitry
• Selectable OFF-delay options
• Gate input wire can be used to selectively inhibit sensor outputs from switching
• Models available with visible red (680 nm) or visible green (525 nm) sensing beam
• Models available with 2 m or 9 m (6.5 ft or 30 ft) cable or integral Pico-style quick-
disconnect
• Sleek, ultra-slim 10 mm housing, mounts to a standard 35 mm DIN rail
* U.S. Patent #5,808,296
Models
Models
Cables*
Discrete Outputs
Analog Output
Red Beam
Green Beam
D10INFP
D10INFPG
2 m (6.5 ft) Cable
NPN
4 to 20 mA
D10INFPQ
D10INFPGQ
6-pin Pico-style QD
D10IPFP
D10IPFPG
2 m (6.5 ft) Cable
PNP
D10IPFPQ
D10IPFPGQ
6-pin Pico-style QD
D10UNFP
D10UNFPG
2 m (6.5 ft) Cable
NPN
0 to 10V
D10UNFPQ
D10UNFPGQ
6-pin Pico-style QD
D10UPFP
D10UPFPG
2 m (6.5 ft) Cable
PNP
D10UPFPQ
D10UPFPGQ
6-pin Pico-style QD
* 9 m (30 ft) cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., D10xFP W/30).
A model with a QD connector requires a mating cordset (see
WARNING: Not To Be Used for Personnel Protection
Never use this product as a sensing device for personnel protection. Doing so could lead to seri-
ous injury or death. This product does NOT include the self-checking redundant circuitry necessary to
allow its use in personnel safety applications. A sensor failure or malfunction can cause either an ener-
gized or de-energized sensor output condition.
D10 Expert™ - Analog and Discrete Outputs
P/N 65448_web
rev. F
7/11/2012
Document Outline
- D10 Expert™ - Analog and Discrete Outputs
- Features
- Models
- Overview
- Programming Options
- Sensor Programming
- Analog Outputs
- Active Channel Select
- Two-Point Static TEACH (Threshold)
- Dynamic TEACH and Adaptive Thresholds
- Single-Point Window SET
- Single-Point Light SET - Discrete Only
- Single-Point Dark SET - Discrete Only
- Manual Adjust
- Sensor Setup
- Advanced Setup
- Push Button Lockout
- Self-Diagnostic Error Modes
- Gate Input
- Specifications
- Installation
- Dimensions
- Hookups
- Accessories
- Banner Engineering Corp Limited Warranty