Sensor setup, Status in setup mode (see, Light/dark operate setting (see – Banner D10 Expert with Numeric Display—Discrete User Manual
Page 12

Sensor Setup
• Configures sensor display and operating parameters
• Changes are updated instantly
• Click Dynamic (+) or double-pulse remote line to select an option
• Click Static (-) or single-pulse remote line to advance
Push Button
Remote
0.04 seconds < T < 0.8 seconds
Result
Access
SETUP
Mode
Press and hold both buttons con-
currently for > 2 seconds.
Double-pulse the remote
line.
T
T
T
Indicator Arrow Icon 1 ON Red
Select
Light/Dark
Operate
Click Dynamic (+) to toggle be-
tween selections.
Double-pulse remote line
to toggle between selec-
tions.
T
T
T
Light Operate
• Display flashes
"lo"
• L icon
Dark Operate
• Display flashes
"do"
• D icon
Click Static (-) to save selection
and advance to "OFF-Delay."
Single-pulse remote line
to save selection and ad-
vance to "OFF-Delay."
T
Select OFF-
Delay Tim-
ing Enable
Click Dynamic (+) to toggle be-
tween selections.
Double-pulse remote line
to toggle between selec-
tions.
T
T
T
Off (No OFF-De-
lay)
• "t 0"
• Clock icon OFF
Click Static (-) to save selection
and advance to "Display."
Single-pulse remote line
to save selection and ad-
vance to "Display."
T
2 to 100 ms OFF-
Delay
• “t 2,” “t 5,” “t 10,” “t 15,” “t 20,” “t 30,” “t 40,” “t 60,”
“t 80,” or “t100”
• Clock icon ON
Select Dis-
play Param-
eters
Click Dynamic (+) to toggle be-
tween selections.
Double-pulse remote line
to toggle between selec-
tions.
T
T
T
Raw Signal Value
Discrete: "1234"
Analog: 4 -20,
0-10, A = mA , V =
Volts
Percent of excess
signal
Discrete: "123P"
Click Static (-) to save selection
and advance to "Power/Speed."
Single-pulse remote line
to save selection and ad-
vance to "Power/Speed."
T
D10 Expert™ - Analog and Discrete Outputs
12
www.bannerengineering.com - tel: 763-544-3164
P/N 65448_web
rev. F