beautypg.com

Status indicators – Banner WORLD-BEAM QS18 Ultrasonic Sensors User Manual

Page 3

background image

Minimum

Operating

Range

Near
Setpoint

Far

Setpoint

Maximum

Operating

Range

Target

Target

Target

Target

Dead Zone

Output

Power

Output

Power

Output

Power

ON:
Green

OFF

Output

Power

OFF

ON:
Green

ON:
Yellow

ON:
Green

OFF

ON:
Red

OFF

Figure 2. TEACH Interface

Status Indicators

Power ON/OFF
LED

Indicates

Output/Teach LED

Indicates

OFF

Power is OFF

OFF

Target is outside window limits (normally open opera-
tion).

ON Red

Target is weak or outside sensing range.

Yellow

Target is within window limits (normally open opera-
ton).

ON Green

Sensor is operating normally, good target.

ON Red (solid)

In Teach Mode, waiting for first limit.

ON Red (flashing)

In Teach Mode, waiting for second limit.

WORLD-BEAM QS18U Ultrasonic Sensors

P/N 119287 Rev. H

www.bannerengineering.com - tel: 763-544-3164

3

This manual is related to the following products: