Specifications – Banner SureCross DX80 Wireless M-GAGE Node User Manual
Page 12

Banner Engineering Corp. • Minneapolis, MN U.S.A
www.bannerengineering.com • Tel: 763.544.3164
12
P/N 131598 rev. F
SureCross™ DX80 M-GAGE™ Node with Integrated Battery
Specifications
Many of the parameters are configurable. The values in the tables represent factory defaults unless otherwise noted.
General
Power
3.6V dc low power option
Mounting
#10 or M5 (M5 hardware included)
M5 Fasteners Max. Tightening Torque
0.56 N•m (5 in•lbf)
Case Material
Polycarbonate
Weight
0.23 kg (0.50 lb.)
Indicators
Two LED, bi-color
Switches
Two Push Buttons
Radio
Range*
300 meters (1000 ft)
Frequency
900 MHz: 902 to 928 MHz ISM band
2.4 GHz: 2.4 to 2.4835 GHz ISM Band
Transmit Power
900 MHz: 21 dBm Conducted
2.4 GHz: 18 dBm Conducted, ≤ 20 dBm EIRP
Spread Spectrum Technology
FHSS (Frequency Hopping Spread Spectrum)
Link Timeout
Defined by Gateway
* The range depends on the environment and line of sight and is lower when buried.
Environmental
Environmental Rating
IEC IP67; NEMA 6
Operating Temperature*
−40 to +85° C (Electronics); −20 to +80° C (LCD)
Operating Humidity
95% max. relative (non-condensing)
Radiated Immunity
10 V/m, 80-2700 MHz (EN61000-6-2)
Shock and Vibration
IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz
* Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.
Compliance
900 MHz Models
FCC ID TGUDX80: This device complies with FCC Part 15, Subpart C, 15.247
IC: 7044A-DX8009
2.4 GHz Models
FCC ID UE300DX80-2400: This device complies with FCC Part 15, Subpart C, 15.247
ETSI/EN: In accordance with EN 300 328: V1.7.1 (2006-05)
IC: 7044A-DX8024
M-GAGE™ Input
Internal Magnetometer
Sample Rate
250 milliseconds
Report Rate
On Change of State
Ambient Temperature Effect
Less than 0.5 milligauss/°C
Sensing Range
See figures 2 and 3