Ez-screen, Ac interface box, Warning – Banner EZ-SCREEN Safety Light Curtain Systems User Manual
Page 9

P/N 120321 rev. C
9
Banner Engineering Corp. • Minneapolis, MN U.S.A
www.bannerengineering.com • Tel: 763.544.3164
EZ-SCREEN
®
AC Interface Box
Model EZAC-R10N-QE8-QS53
• Two N.O. relay contacts
• Power monitoring (EZ-SCREEN must be configured for E2)
• QD: 5-pin Mini-style for I/O, and a 3-pin Mini-style for power and ground
%:!# 2. 1% 13
.EUTRAL
.
.
,
,
,INE
'ND
%$-
+
+
%$-
-ACHINE
#ONTROL
'N9E
7H
./
./
./
./
"K
"U
"N
'N9E
"N
"U
-0#%
-0#%
!RC
8
8
8
8
-ONITORING
#ONTACTS
-0#%
-0#%
3-Pin Mini-Style Power Connector
Male Face View
5-Pin Mini-Style Output Connector
Male Face View
Mating Cable: QDS-3..C
Mating Cable: QDS-5..C
Pin
Color
Function
Pin
Color
Function
1
Green/Yellow
Gnd/PE
1
Black
N.O. (1a)
2
Brown
Line
2
Blue
N.O. (2a)
3
Blue
Neutral
3
Green/Yellow
Gnd/PE
4
Brown
N.O. (2b)
5
White
N.O. (1b)
'REEN9ELLOW
WIRE
"ROWN
WIRE
"LUE
WIRE
"LACK
7HITE
"ROWN
"LUE
'REEN9ELLOW
Figure 9. Hookup – model EZAC-R10N-QE8-QS53
WARNING ...
Wiring of Arc
Suppressors
If arc suppressors are used, they MUST be
installed as shown across the actuator coil of
the Machine Primary Control Elements (MPCE1
to MPCE2). NEVER install suppressors
directly across the output contacts of the
Safety Module. It is possible for suppressors to
fail as a short circuit. If installed directly across
the output contacts of the Safety Module, a
short-circuited suppressor will create an unsafe
condition which could result in serious injury or
death.