D10 — discrete output, Specifications, Installing fibers – Banner D10—Discrete User Manual
Page 2

Banner Engineering Corp. • Minneapolis, MN U.S.A
www.bannerengineering.com • Tel: 763.544.3164
2
P/N 118431 rev. A
D10 — Discrete Output
Figure 1. D10 Bipolar Discrete sensor features
L O
DO
0 ms
40 ms
+
-
DELAY
Yellow Signal
Strength LED
LED flashes
to indicate received
signal strength
Green
Power ON
LED
12-Turn Sensitivity (Gain)
Control and Indicator
Turn Sensitivity control
clockwise to increase Gain
LO/DO Select
Switch
Delay Selector
Switch
Specifications
Sensing Beam
660 nm visible red or 525 nm visible green, depending on model
Supply Voltage
10 to 30V dc (10% max. ripple) @ less than 25 mA, exclusive of load
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Bipolar: 1 current sourcing (PNP) and 1 current sinking (NPN)
Output Rating
100 mA per output with short circuit protection
OFF-state leakage current: < 10 µA sourcing; 200 µA sinking
ON-state saturation voltage:
NPN: 1.6V @ 100 mA
PNP: 2.0V @ 100 mA
Output Protection
Protected against output short-circuit and false pulse on power up (max. 100 ms delay on power up;
outputs do not conduct during this time)
Output Response Time
Standard models (with crosstalk avoidance circuitry): 500 microseconds
High-speed models: 200 microseconds
Repeatability
Standard models: 95 microseconds
High-speed models: 50 microseconds
Adjustments
12-turn Sensitivity potentiometer with relative position indicator; LO/DO Selection switch; 0 or 40 ms off-
delay switch
NOTE: Use proper ESD techniques while making adjustments under cover.
Indicators
Two LEDs: Green and Yellow
Green ON steady: Power ON
Yellow flashing: Light Sensed Signal strength indicator (Banner’s AID™ Alignment Indicating Device
– the faster the flash, the more light is received)
Construction
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover
Environmental Rating
IEC IP50; NEMA 1
Connections
2 m or 9 m (6.5' or 30') attached cable, or 4-pin Pico-style quick-disconnect fitting;
cables for QD models are purchased separately
Operating Conditions
Temperature: −10° to +55° C (+14° to 131° F)
Storage: −20° to +85° C (−4° to +185° F)
Relative Humidity: 90% @ 55° C (non-condensing)
Certifications
Installing Fibers
Plastic Fiber
Emitter Port
Plastic Fiber
Receiver Port
Slides Up to
Release Fibers
DIN Rail (or included mounting bracket)
Figure 2. Installing D10 fibers and housing