Calculated Industries 5060 User Manual
Page 12
![background image](/manuals/585194/12/background.png)
10 — ElectriCalc Pro
V — Volt-Amps
Enters or calculates volt-amps (using
amps, volts and horsepower or watts).
Displays: VA KVA, or mVA.
W — Watts
Enters or calculates watts (using amps,
volts, and VA or horsepower).
Displays: WATT KW, or mW.
S W —Power Factor
Enters or calculates power factor per-
centage (based on watts and VA). De-
faults to 100%. Entered or calculated
power factors greater than 100% will
result in an error. Displays: PF%.
H — Horsepower (Theoretical)
Enters or calculates theoretical horse-
power (based on amps, VA, watts,
efficiency%, PF%, and/or volts). 1.0
HPth correlates to 746 watts at 100%
efficiency. Displays: HPth.
S H — Efficiency
Enters or calculates the percent ratio
between real power (watts) and theo-
retical horsepower. Default: 100%.
Entered or calculated efficiencies
greater than 100% will result in an error.
Displays: EFF%.
S • (Kw-hr
ᮣ
Btu) — Kilowatt
Hours to BTU function. Calculate
BTU (British Thermal Unit) based on an
entered Kilowatt Hour value.