Bird 8640 Series Moduload RF Load Resistor

26

14. Run the pump for five minutes and check for leaks before applying

RF power.

Conductor

Replacement

1. Use a

3

16

allen wrench to remove the cap screws [16] from the RF

connector.

2. Remove the outer conductor assembly [12].

NOTE: If only the outer conductor needs replaced, install it now
and screw it into place.

3. Remove the center conductor assembly [11] by pulling it carefully

out of the load housing. Make sure the resistor [1] and inner flow
tube [9] do not come out with the center conductor.

4. Insert the new center conductor assembly into load housing. Make

sure the resistor fitting makes a snug fit with the resistor.

5. Replace the outer conductor and screw it into place.