Maintenance

21

9. Record the wire colors and locations then disconnect the pump

motor wires from the front panel terminal block (TB 1) (Figure 8).

10. Remove the screws that secure the front panel to the unit then tilt

the top of the panel away from the unit and remove the two water
hoses from the load water pipes.

11. Remove the front panel with the load attached.

12. Remove the nuts and lock washers that secure the load to the

panel.

13. Remove the socket head cap screws that secure the water chamber

to the load then remove the water chamber.

14. Inspect the water chamber to be sure it is in good condition and

that the inner o-ring seal is good. If appropriate, order
replacement parts.

Figure 8

Front Panel Wiring

YEL

GRN / YEL

WHT

BLK

GRN / YEL

WHT

WHT

BLK

BLK

ORG

GRN / YEL

BLK

RED

WHT

BLK