3. Secure the new fan capacitor bracket assembly to the fan inverter assembly
using the two M5 x 10 mm POZIDRIV screws provided in the kit.
Tightening torque is 4 N
•
m (35 lb
•
in).
4. Install the fan inverter assembly in the reverse order of removal as detailed
in
Step 3
Remove the Existing Fan Capacitor
on page
7
.
Secure capacitor
bracket assembly to fan
inverter assembly using
two screws provided