Rockwell Automation 20D PowerFlex 700H/S Frame 13 Replacement Power Structures User Manual
Page 12
![background image](/manuals/581667/12/background.png)
12
PowerFlex® 700S and 700H Frame 13 Replacement Power Structures
Step 4: Connecting the
Power Structure to
Components in the Drive
1. For drives with AC input, connect the precharge cable and remove the
jumper from the fan control connector and connect the fan control cable
from the Rectifying modules to the Power Structure.
2. Use the tables and illustrations below to make all connections between
the ASIC, Power Supply Voltage Feedback and Fiber Optic Interface
(700S) or Fiber Optic Adapter (700H) and Common Mode Filter circuit
boards for your installation.
– Refer to
PowerFlex 700S Phase II Drive Connections: on page 15
for
a PowerFlex 700S circuit board connection diagram.
– Refer to
PowerFlex 700H Connections: on page 16
for a PowerFlex
700H circuit board connection diagram.
Important: If the drive has DC input, you must also connect the
precharge circuit. Refer to
Drives with DC Input on page 18
.
=
Connect fan control
cables
Connect Precharge
cables