Additional resources – Rockwell Automation HPK-Series Motor Encoder Replacement Installation Instructions User Manual
Page 11
![background image](/manuals/581500/11/background.png)
HPK-Series Motor Encoder Replacement Kit 11
Rockwell Automation Publication HPK-IN002C-EN-P - May 2012
9. Install the white motor thermostat leads (P1 and P2) to the thermostat connectors (9).
a. Slide the plastic sleeving over the connector and fasten the sleeving with electrical
tape.
b. Tape each lead individually, and then tape the two leads together.
10. Use wire ties to secure the encoder cable and thermostat leads to the motor frame.
Restrain all cables and wires to prevent contact or entanglement with rotating fan blades,
the motor, or moving parts on machine.
11. Slide the encoder cable into the slot on the fan cover, or rear cover, and then mount the
cover on the motor bracket.
12. Mount the encoder connector (10) to the top of the fan cover with four screws.
Additional Resources
For additional information on the HPK-Series encoders, refer to HPK-Series Motor Installation
Instructions, publication
You can view or download publications at
. To
order paper copies of technical documentation, contact your local Allen-Bradley distributor or
Rockwell Automation sales representative.
TIP
The encoder connector typically points in the same direction as the lead outlet on the motor
conduit box.
Use the
HPK-Series Motor Encoder - Later Version
diagram as a visual reference during removal
and installation of the encoder.