Table A.1 – Service Conditions
AC Line Distribution System Capacity
(maximum) for 460 VAC Units
85,000 amps symmetrical fault current capacity. Short circuit
rating may be limited to 65,000 amps if a circuit breaker is
used instead of fuses.
Control Method
All-digital vector, sinusoidal pulse-width-modulated (PWM)
Displacement Power Factor
0.96
Line Frequency
50/60Hz (
±
2 Hz)
Line Voltage Variation
-10% to +10%
Line Dip Ride-Through
FVC: Maximum 500 milliseconds
V/Hz, SVC: Adjustable up to 999.9 seconds (See P.042)
Motor Lead Lengths
76 meters (250 feet) total
Remote Operator Control Wire Length
Up to 303 meters (1000 feet) from the drive
Analog Speed Reference Resolution
1/1024 (10 bits) 0.1%
Acceleration Adjustment Range
0.1 to 999.9 seconds (within the ability of current)
Carrier Frequency
2 kHz, 4 kHz. or 8 kHz (software-selectable)
Current Limit Adjustment
Vector: U.006 to 150% (based on motor nameplate rating)
V/Hz: 50% to 110% (based on drive nameplate rating)
Service Factor
1.0
Speed Adjustable Range
From 0 RPM to maximum speed (vector)
Speed Regulation
Vector: 0.01% FVC, 0.5% SVC (steady state)
V/Hz: Motor slip dependent
Speed Reference Resolution
1 RPM with local keypad, -4095 to +4095 counts with a
network or serial reference
Torque Control Response
180 to 220 Hz
Torque Linearity
+3% with optimal parameter setting (typical)