Upgrading from a previous version – Rockwell Automation Emonitor with a Gupta Single-User Database User Manual
Page 7

1
•
I
NTRODUCTION
3
•
•
•
• •
are additional disk space requirements depending on your database setup. Be sure to
check with your database administrator about these requirements and about backing up
your database.
B
E
SURE
YOU
HAVE
THE
CORRECT
VERSION
OF
THE
DATABASE
SOFTWARE
INSTALLED
.
On the computer hosting the Emonitor software:
Before installing Emonitor, make sure the database version is compatible. You might
need to consult with your database administrator to verify which version of the
database server you are using. The Gupta SQLBase database version supported by
Emonitor is SQLBase version 9.0.1.
B
E
SURE
YOU
HAVE
W
INDOWS
7 P
ROFESSIONAL
INSTALLED
.
Before installing Emonitor, you need to have the Windows 7 Professional, Enterprise, or
Ultimate operating system installed on your computer. Emonitor version 3.70 is supported
on the 32-bit versions of Microsoft Windows 7 Professional, Enterprise and Ultimate.
Emonitor version 3.70 is not supported on the Windows NT, Windows Vista, Windows
2000 Pro, Windows 2000 Server, Windows XP, Windows Server 2008 or 64-bit versions
of Windows 7 operating systems.
Upgrading from a previous version
Emonitor version 3.70 runs only on the Windows 7 operating system. This means that you
cannot directly upgrade Emonitor running on an earlier version of Windows (Emonitor
3.50 was not supported on Windows 7). Instead, you must follow these steps:
1. Install Emonitor version 3.70 on a computer running Windows 7,
2. Move your Emonitor database and Emonitor configuration files to the computer
where you installed Emonitor version 3.70.
Refer to the chapter titled Upgrading from a previous version. A new feature of the
upgrade process is that the installation program asks if you want to back up your Emonitor
configuration files. This includes all the data collector INI files, as well as any
configuration files for any of the Emonitor programs (such as the Emonitor Scheduler and
the Emonitor Online components). This allows you to protect your configuration files
during an upgrade, and then bring them back into the new version.
If you are upgrading from a version of Emonitor prior to 3.20 (including Emonitor for
Windows (EFW), Odyssey, or IQ 2000), please contact Customer Support for assistance.
Additional steps are required to upgrade from the 16-bit to 32-bit software. See Statement
of Technical Support on page 4 for contact information.