Enwatch Technical Specifications
Product Feature
Specification
Inputs
Number of Channels
16 vibration and 4 tachometer (synchronizer)
Voltage Protection
Protects against over-voltage (channel auto-switch off)
2000 V ESD protection
Input Impedance
1 M
Ranges
±10 mV… ±10 V, 7 ranges (software selectable)
ICP Interface
3.6 mA @ 24V DC, configurable per channel
Coupling
AC/DC (numeric measurements), configurable per channel
DC offset removal by optional use of channel 16
PGA Gains
Set when a route is loaded by the Emonitor software
Anti-alias Filter
Compound analog filter with roll-off better than 20th order filter; cut-off frequency related to sample rate.
High-pass Filters
4th order with corner frequencies 0.36, 2.67, 5.3, and 23.8 Hz
Channel Cross-Talk
-80 dB
Amplitude Accuracy
±2% typical in pass-band
Phase Accuracy
±3%
Harmonic Distortions
-70 dB (typical)
Integration
One 2-stage with ideal stop-band edge at 0.36 Hz
Acquisition Modes
Mode 1: Timed pickup
Mode 2: Data Ready flag
Mode 3: Data broadcast
Spike Energy Measurement
gSE Filters
High pass at 200 Hz & 5 kHz 2nd order
Triggers
Types
TTL Isolated or Non-Isolated, or any voltage up to +24 V
Maximum combined current for all channels, not to exceed 100mA
Machine Speed Range
1 to 60,000 RPM
Time to Lock
2 revolutions
Averaging
1, 2, 4, ... 32,000 averages, programmable
Tachometer Information
RPM using trigger input
Trigger Delays
Post-trigger delays up to 32,768 samples
Pre-trigger delays up to 16,384 samples
(not used with the Emonitor software)
Processing
Time Domain ADC
16 bit
Sampling Rate
64 Hz to 51.2 kHz
Dynamic Range
96 dB (theoretical)
Block Lengths
256, 512, 1024, 2048, 4096, or 8192 with averaging
up to 16,384 without averaging
Overall Units
Acceleration, velocity, or displacement (double integration in one level hardware & one level software), and Spike
Energy data
Outputs
Status
LEDs indicate system functions
Interface Port
RS232C, 9600 baud for diagnostics
Storage
Memory Buffer
640 KB