Operation mode: Stepping operation
Operation mode: Stepping operation with key switch
Monitoring of the machine contact
2 ways of monitoring are selectable:
Mode 1
In this mode the access to the LC must only be done when the machine
contact has been openend and closed again. An exception is when the
access is done while the contact is open and still is going on while the
contact closes.
Forbidden access into the light curtain
On forbidden access the lamp (on terminal 58) shows symmetric fl ashing.
The lamp on terminal 48 fl ashes with code 1. After fi nishing the access the
lamp on terminal 58 returns to permanent light and signalises, that the
machine can be started with the start button.
Stepping operation with key switch
e.g. Presses witch changing number of accesses
Selection with key switch: 1, 2 or 3 steps
Enable new setting
A changed number of steps is only recognised at standstill (K1 and K2 open).
A new number of steps is signalised by failure indication 3 on the lamp
(terminal 48). Pressing the start button will restart the unit. After that the
normal start sequence complete swith start button and number of accesses
must be completed to enable the machine with the new number of steps.
Mode 2
In this mode the accesses are accepted already when the machine contact is
open. The machine is only enabled when all the accesses are completed and
the machine contact is closed again.
Applictaion:
Presses with normal to fast movement
M8048_b
LC 1 (S12/S14)
Machine contact
(S41/S42)
K1, K2
(13-14, 23-24, 33-34)
wait for access (48)
wait for start (58)
: on
: dark
: flashing 3Hz
Application:
Presses with slow movement
M8049_b
LC 1 (S12/S14)
Machine contact
(S41/S42)
K1, K2
(13-14, 23-24, 33-34)
wait for access (48)
wait for start (58)
: on
: dark
: flashing 3Hz
M8050_b
Start button (S43/S44)
LC 1 (S12/S14),LC 2
(S22/S24) o. LC 3 (S32/S34)
Machine contact
(S41/S42)
K1, K2
(13-14, 23-24, 33-34)
wait for access (48)
wait for start (58)
: on
: flashing 1Hz
: error code
: off