beautypg.com

Rockwell Automation 36С47 DC Drive Output Contactor Kit 300-500HP User Manual

Description, Installation

background image

INSTRUCTION SHEET D2Ć3017Ć2

OUTPUT CONTACTOR KIT

Models 36C47

For use with 300, 350, 400 and 500 HP

460 VAC, ThreeĆPhase Input

General Purpose or Variable Torque

AĆC V

L

S

R

Drives

WARNING

BEFORE INSTALLING AND/OR OPERATING

THIS KIT, THE QUALIFIED ELECTRICAL

MAINTENANCE PERSON WHO IS FAMILIAR

WITH THIS TYPE OF EQUIPMENT AND THE

HAZARDS INVOLVED SHOULD READ THIS

ENTIRE INSTRUCTION SHEET. FAILURE TO

OBSERVE THIS PRECAUTION COULD REĆ

SULT IN BODILY INJURY.

DESCRIPTION

The Reliance Electric Output Contactor Kit provides a

positive disconnect (contactor) between the output of the

AĆC VLSR Drive Controller and the Drive Motor. A

controller Start command will cause the contactor to be

energized. The controller start sequence will be inhibited if

the AĆC Contactor's auxiliary contact does not close (N"

auxiliary signal). When the Stop rocker switch is pressed,

the AĆC Contactor will drop out immediately if the

controller is set for coastĆtoĆrest or will drop out after zero

speed is reached if the controller is set for coastĆtoĆrest or

will drop out after zero speed is reached if the controller is

set for rampĆtoĆrest. When an instantaneous electronic trip

(IET) occurs, the AĆC Contactor will drop out immediately.
Upon receiving, check the contents of the kit received with

the contents as listed in Table 1. Store this equipment in a

clean and dry area until ready to use. The ambient

temperature of the storage area must not exceed 65

o

C

(149

o

F) or go below -40

o

C (-40

o

F).

INSTALLATION

NOTE: All components of the Output Contactor Kit must be

mounted in a clean and dry environment. Maximum

ambient temperature must not exceed 40

o

C outside the

cabinet (55

o

C inside the cabinet).

WIRE SIZING NOTE: Care should be taken to see that all

interconnecting wiring is sized and installed in

conformance with the National Electric Code (NEC),

published by the National Fire Protection Association, or

the Canadian Electrical Code (CEC), and other applicable

local codes.

Table 1 Complete parts listing.

Description

Qty.

Part Number

Contactor

Auxiliary Contact (NO)

Connector

Control Transformer

Fuse Block

Fuse

Relay Socket

Relay

Cover

Wire Harness

Wire Harness

Wire Harness

Wire Assembly

Wire Assembly

Wire Assembly

Wire Assembly

Hex Washer Head Screw

ăă(5/16Ć18 x 1/2")

Hex Head Cap Screw

ăă(1/4Ć20 x 3/4")

Flat Washer (1/4")

Lock Washer (1/2")

Hex Head Cap Screw

ăă(1/2Ć13 x 1 1/4")

Flat Washer (1/2")

Lock Washer (1/2")

Taptite Screw (10Ć32 x 1/2")

Taptite Screw (8Ć32 x 1/2")

Taptite Screw (6Ć32 x 1/2")

Hex Head Cap Screw

ăă(1/4Ć20 x 1 1 /4")

Spacer

TyĆRap

1

1

3

1

1

1

1

1

1

1

1

1

1

1

1

1

4

6

8

8

3

3

3

5

2

2

2

2

10

705310Ć9R

76624ĆX

610290Ć57A

417155ĆS

49454ĆA

64676Ć1P

600434Ć5R

600434Ć6R

705321Ć15R

705337Ć35R

801553Ć34R

801553Ć35R

608809Ć12SA

608809Ć12X

608809Ć12RX

608809Ć12SC

601741Ć73B

601741ĆC

601748Ć1E

601748Ć3J

601741Ć8AB

601748Ć1J

601748Ć3N

601741Ć63C

601741Ć62D

601741Ć61D

601741ĆAB

400684ĆB

69306Ć3D