Hardware, Typical synchronous starter components – Rockwell Automation 1901 SyncPro User Manual
Page 9

Product Description
1-5
1901-UM020C-EN-P – June 2013
Hardware
The system consists of the following hardware:
•
SyncPro
5/03 Processor
:
•
1747-L532
EEPROM
•
1746-ITB16
High Speed DC Input Module
•
1746-NIO4I
Analog Input/Output Module
•
1746-0X8
Isolated Relay Output (or any 8-point output)
•
1746-IA16
120VAC Input Module (or any 16-point input)
•
1746-A7
7-Slot Rack
•
1746-P1
Power Supply
•
1747-DTAM
Data Table Access Module
•
700-F220A1
Interposing Relay (FCR, ESR)
•
80165-998-51
Phase Angle Transducer
•
80025-817-01
20 kilohm Tapped Conditioning Resistors
•
80165-778-51
Analog/Digital Pulse Board
•
800T-PB16R
Red Illuminated Push Button
:
Contains specialized patented hardware for synchronous application on EEPROM
that cannot be viewed/accessed.
The following list of components are devices which the SyncPro is
connected to, or are part of the SyncPro protection package.
Motor Contactor (M)
The motor contactor is used to provide and switch the power
supplied to the motor stator. It is controlled by the SyncPro
package and is necessary to remove stator power in the event of a
stop command or a trip condition. Two normally open contactor
auxiliaries may be required; one mandatory N.O. contact to give
contactor status information to the SyncPro, and one may be
needed as a hold-in contact for the main control circuit.
Motor Contactor Pilot Relay (CR1 or MR)
This interposing relay allows the SyncPro output to pick up the
main contactor coil. The power requirements of the pick-up coils
used in most medium voltage motor starters would exceed the
switching capability of the 1746-OX8 output contact.
Typical Synchronous Starter