beautypg.com

Rockwell Automation 6180 6180 Industrial Power Supplies Installation Instructions User Manual

Page 4

background image

4

Power Supplies

Publication 6180-5.8

2.

Connect the power supply cable connectors to the processor board
and other internal components. The connectors are keyed so they
cannot be installed the wrong way, do not force connectors.

ATTENTION: Make sure the flow director is properly
positioned between the power supply and base of the
processor socket. Failure to correctly install the flow
director may result in excessive temperatures which can
damage the processor.

3.

Make sure the flow director is positioned correctly.

On Pentium systems, the flow director is directed at the base of
the processor socket. The flow director tabs are inserted into the
power supply below the fan. The free end of the flow director is
positioned against the base of the processor socket.

On Pentium II and Pentium III systems, the flow director is
attached to the power supply. The flow director surrounds the
slot 1 processor module and draws air away.

4.

Install the power supply filter, if applicable (Pentium II and DC
powered systems do not require power supply filters).

5.

Install the back panel.