Power Supplies

Publication 6180-5.8

To remove the power supply:

1.

Disconnect power from the 6180 Computer.

2.

Remove the back panel.

3.

Unplug the power cord from the power supply.

4.

Remove the power supply filter.

5.

Follow the wires as they exit the power supply and disconnect the
wiring at the connectors. Pull on the connector to remove, do not
pull on the wires. Make sure you note the location of the connectors.
Connectors P1 and P10 have latches that must be squeezed before
the connector can be removed.

6.

While supporting the power supply, remove the 5 mounting screws
that secure the power supply.

7.

Remove the power supply.

Power Supply
Mounting Screws (5)

Filter

Pentium System

Power Supply

Danger Labels - Screw Size
(see Attention Next Page)