Rockwell Automation 1753-IB16XOB8 GuardPLC 16-Digital Inputs and 8-Digital Outputs Installation Instructions User Manual
Page 19

GuardPLC 16-Digital Inputs and 8-Digital Outputs Module 19
Publication 1753-IN011A-EN-P - October 2005
Digital Output Terminals
See page 22 for the appropriate wire size. Digital outputs are connected to the
following terminals:
Terminal Number
Designation
Function
1
S+
Reference pole for negative-switching digital outputs
2
S+
Reference pole for negative-switching digital outputs
3
S+
Reference pole for negative-switching digital outputs
4
S+
Reference pole for negative-switching digital outputs
5
S-
Reference pole for positive-switching digital outputs
6
S-
Reference pole for positive-switching digital outputs
7
S-
Reference pole for positive-switching digital outputs
8
S-
Reference pole for positive-switching digital outputs
9
1-
Digital output 1, negative-switching
10
1+
Digital output 1, positive-switching
11
2-
Digital output 2, negative-switching
12
2+
Digital output 2, positive-switching
13
3-
Digital output 3, negative-switching
14
3+
Digital output 3, positive-switching
15
4-
Digital output 4, negative-switching
16
4+
Digital output 4, positive-switching
17
5-
Digital output 5, negative-switching
18
5+
Digital output 5, positive-switching
19
6-
Digital output 6, negative-switching
20
6+
Digital output 6, positive-switching
21
7-
Digital output 7, negative-switching
1
2
3
4
5
6
8
7
S+
DO
DO
S+ S+ S+ S- S- S- S-
9 10 11 12 13 14
16
15
1- 1+ 2- 2+ 3- 3+
4+
4-
5- 5+ 6- 6+ 7- 7+
8+
8-
17 18 19 20 21 22
24
23