12 ControlNet Adapter Module

Publication 1747-IN017C-EN-P - May 2001

Connecting Programming Terminals to the Network via the NAP

You can connect programming terminals to the ControlNet network by connecting
to the network access port (NAP). Two methods are shown below.

ATTENTION

!

Use the 1786-CP cable when connecting a programming
terminal to the network through NAPs. Using a commercially
available RJ-style cable could result in possible network
failures.

Using 1784-KTC or -KTCx communication card
and NAP

Programming
Terminal

1784-KTC or
-KTCx

1786-CP

1

ControlNet
product

ControlNet network

Using 1770-KFC communication
interface and NAP

Programming
Terminal

Serial or Parallel
Connection

ControlNet Network

1. The 1786-CP cable can be plugged into any ControlNet product’s NAP to provide programming capability on the

ControlNet network. A programming terminal connected through this cable is counted as a node and must have a
unique address.

1786-CP

1

1770-KFC

ControlNet
product