Rockwell Automation 1734-SSI POINT I/O Synchronous Serial Interface Absolute Encoder Module User Manual User Manual
Page 28

Publication 1734-UM007D-EN-P - December 2005
3-6 Communicate with Your Module
Gray to Binary Conversion
No/Yes
Convert data from Gray to
binary
SSI Word Delay Time (t
m
)
16
µs… to 64ms (64µs)
Delay time between
successive SSI data words
SSI Word Filter Control
Off, Low, Med, High, Max
Corresponds to the number
of successive equal SSI data
words that must be received
by the module in order to
update the real-time present
SSI data word.
Standardization
Off/On
Off = Use entire data word
length specified by Data
Word Length parameter.
On = Data is right-shifted
the number of bits specified
in the Trailing Bits
parameter.
Trailing Bits
0… 16
Sensor Resolution
1… 65535
Total number of
positions/revolution for a
rotary encoder,
positions/stroke for a linear
displacement transducer, or
maximum counts for
distance measurement.
Sensor Cycles
1… 65535
Total number of revolutions
for a rotary encoder, strokes
for a linear displacement
transducer
Latch Input
Off, Rising Edge, Falling
Edge, Both Edges
Master unlatches data by
transmitting the LACK bit
over the network
Comparator 1
Not Active, Up Direction,
Down Direction, Both
Directions
Module compares data to
value from the master. Only
one Compare value can be
active.
Comparator 2
Not Active, Up Direction,
Down Direction, Both
Directions
Module compares data to
value from the master. Only
one Compare value can be
active.
(1)
Default values are in bold.
Parameter
Value
(1)
Notes