Rockwell Automation 1792D-8BT8PE ArmorBlock MaXum 8 In/8 Out Module with Ground Lug User Manual
Page 16
![background image](/manuals/579205/16/background.png)
16 ArmorBlock MaXum 8 Input / 8 Output Module With Ground Lug
Publication
1792D-IN055A-EN-P - October 2004
General Specifications
Maximum
Minimum
DeviceNet Power
Voltage
Current
25V dc max
150mA max (no sensors)
11V dc min
up to 1.4A (8 sensors @
50mA per sensor)
Auxiliary Power
Voltage
Current
30V dc max
4A max
10V dc min
4A max
Indicators
Net/Mod Status - red/green
Logic Status - green
Auxiliary Power - green
Point LED - yellow/orange/red
Communication Rate
•
125Kbps @ 500 meters(1600 feet) for thick cable, flat
media length 375 meters (1230 feet)
•
250Kbps @ 200 meters(600 feet) for thick cable, flat
media length 150 meters (492 feet)
•
500Kbps @ 100 meters (330 feet) for thick cable, flat
media length 75 meters (246 feet)
Dimensions (assembled to base)
inches - (Millimeters)
1.9H x 2.7W x 6.9D
(48)H x (69)W x (174)D
Operational Temperature
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-25 to 60
°
(-13 to 140
°
F)
Storage Temperature
IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold),
IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat),
IEC 60068-2-14 (Test Na, Un-packaged Non-operating Thermal
Shock):
-25 to 80
°
(-13 to 176
°
F)
Relative Humidity
IEC 60068-2-30 (Test Db, Un-packaged Non-operating Damp
Heat):
5 to 95% non-condensing
Vibration
IEC 60068-2-6 (Test Fc, Operating):
10g @ 10-500 Hz
8 Input / 8 Output Module - Cat. No. 1792D-8BVT8PE