Dr83dancer parameters – soft fault, Multi-comm fault messages, Rio faults – Rockwell Automation 1395 Reel Tension Paster Adapter User Manual
Page 45: Dh+ only faults

Publication 1395-RTP-5.1 - September 1997
Troubleshooting
4-5
DR-83-Dancer Parameters – Soft Fault
The dancer parameters corresponding to dancer center, dancer mid,
(midpoint between center and full), and dancer full, (Parameters 560,
559, and 558 respectively, must be given values in the proper numeric
sequence. Dancer full, Parameter 558, must be greater than dancer
mid, P559. Dancer mid must be greater than dancer center, P558.
Internal Drive logic of the Digital Reference Adapter Board has
reached an invalid state. Clear fault, power down, and reapply power.
If not solved, “INITIALIZE” EEPROM; re-download links and
Parameters; “SAVE” to EEPROM; then “CLEAR FAULTS.” If not
solved, replace Digital Reference Adapter.
Multi-Comm Fault Messages
Message:
CA–64–ADAPTER PROCESSOR FAULT
CA–65–ADAPTER PROCESSOR FAULT
CA–66–ADAPTER PROCESSOR FAULT
CA–67–ADAPTER PROCESSOR FAULT
Fault Type: Hard
Cause:
Adapter internal diagnostic malfunction.
Action:
Check dip switch settings and reset drive, if condition
persists replace adapter board.
RIO Faults
Message:
CA–70–RESET/PROGRAM/TEST (CHA)
CA–85–RESET/PROGRAM/TEST (CHB)
Fault Type: Soft/Warning
Cause:
PLC was switched from run mode to another mode.
Action:
Check PLC mode switch and I/O control reset; if
condition persists, replace adapter board.
Message:
CA-71-RIO COMM LOSS (CHA)
CA-86-RIO COMM LOSS (CHB)
Fault Type: Soft/Warning
Cause:
Loss of communication between adapter and PLC.
Action:
Check wiring and connections, verify adapter is being
scanned, if condition persists, replace adapter board.
DH+ only Faults
Message:
CA–75–DUP NODE ADDR (CHA)
CA–90–DUP NODE ADDR (CHB)
Fault Type: Soft/Warning
Cause:
One or more nodes with the same address exist on the
DH+ network.
Action:
Check that each node has a different address, if
condition persists, replace adapter board.