E - doc, Install wire to lugs, Revision authorization – Rockwell Automation 1494V-DS400_DS600 Disconnect Switch (400/600A - Series A) User Manual
Page 5: Sheet
(5)
* When lug kits 1494R-N10 & 1494R-N11 are used.
4
Install Wire to Lugs
T
T
L2
L1
L3
8 lb-in
Trailer
Fuse
Fuse
Fuse Block
Fuse Clip
Wire to
Fuse Block
Clip
Block
Mtg. Screw
Mtg. Screw
Lug
Catalog
Catalog
V
X
Y
Q
R
S
T *
Z
Mounting
Torque
Torque
Torque
Number
Number
(inches)
(inches)
(inches)
(inches)
Screw
(lb-ins.)
(lb-ins.)
(lb-ins.)
400A, 250V
H
3/16
6-3/4
5/16-18
30
275
325
400A, 250V
R
3/16
6-3/4
5/16-18
30
275
325
400
400A, 600V
H
3/16
6-3/4
5/16-18
30
275
325
400A, 600V
J
3/16
6-3/4
5/16-18
30
275
325
400A, 600V
R
3/16
6-3/4
5/16-18
30
275
275
275
275
275
275
325
325
325
325
325
325
400A, 250V
R
23/64
6-3/4
5/16-18
400A, 600V
H
23/64
6-3/4
5/16-18
30
275
325
400A, 600V
J
23/64
6-3/4
5/16-18
30
275
325
400A, 600V
R
23/64
6-3/4
5/16-18
30
90-110
90-110
90-110
90-110
90-110
90-110
90-110
90-110
90-110
90-110
30
275
325
90-110
90-110
90-110
90-110
275
325
Term
Screw
or
Stud
1/2-13
1/2-13
Lug to
Terminal
Torque
(lb-ins.)
2-11/16
2-11/16
5-11/16
1-3/16
5-11/16
1-3/4
4-1/4
1-3/32
4-1/4
600
600A, 250V
H
5/16-18
- - -
275
325
600A, 250V
R
5/16-18
- - -
275
325
600A, 600V
H
5/16-18
- - -
275
325
600A, 600V
J
23/64
6-3/4
5/16-18
225
275
325
600A, 600V
R
5/16-18
- - -
60
60
60
90-110
60
275
325
4-13/32
1494V-FS400
1494V-FS400
1494V-FS400
1494V-FS400
1494V-FS400
1494V-FS400
1494V-FS400
1494V-FS400
1494V-FS400
1491-N621
1491-R621
1491-N621
1494V-FS600
1491-R621
1401-N46
1401-N55
1401-N46
1401-N46
1401-N55
1401-N55
1401-N46
1401-N46
1401-N55
(1)
(1)
(1)
(2)
(1)
3-15/16
3-15/16
3-15/16
3-15/16
3-15/16
3-15/16
3-15/16
3-15/16
3-15/16
3-15/16
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
Switch
Fuse
Rating
Rating
Fuse
Class
(Amps)
(Amps/Volts)
400A, 250V
H
23/64
6-3/4
5/16-18
30
275
325
90-110
1-3/4
1494V-FS400
1401-N46
3-15/16
200A, 250V
H
5/16-18
20
20
20
20
20
200A, 250V
R
3/16
6-3/4
5/16-18
200A, 600V
H
6-3/4
5/16-18
200A, 600V
R
3/16
3/16
3/16
3/16
6-3/4
6-3/4
6-3/4
5/16-18
200A, 600V
J
5/16-18
1-17/32
1-17/32
4-1/32
29/32
4-1/32
3-61/64
1494V-FS400
1494V-FS400
1494V-FS400
1494V-FS400
1494V-FS400
1401-N45
1401-N54
1401-N45
1401-N54
1401-N45
3-61/64
3-15/16
3-15/16
3-15/16
AA
(inches)
BB
(inches)
CC
(inches)
3-3/16
2-13/16
3-3/16
2-13/16
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
3-3/16
2-13/16
3
3
3
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
1025456
2
DISCONNECT SWITCH AND ACCESSORY KITS
INSTALLATION INSTRUCTION SHEET
1
1006259
42052-073
OF
N/A
N/A
N/A
REVISION
AUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.
SIZE
SHEET
B
1
2
3
4
5
6
7
8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORE
SURFACE TREATMENT
(DIMENSIONS IN INCHES)
TOLERANCES UNLESS
OTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
---------------
---------------
---------------
---------------
---------------
---------------
5
8
THIS DRAWING IS THE PROPERTY OF
ROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,
USED OR DISCLOSED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
2
1
3